XOS - US
Get eNewsletter   1.518.880.1500 Service

Clora R Series

Meet the R Series

Clora R Series chlorine analyzer

 


Clora R

Analyze Total Chlorine with Unparalleled Precision

The Clora R ® compact analyzer measures total chlorine in hydrocarbons such as aromatics, distillates, heavy fuels, crude oils, and water.

This state-of-the-art technology complies with ASTM D7536 and D4929C and delivers unparalleled accuracy and precision for petroleum and petrochemical applications where simple, quick, and reliable analysis is critical. *

 

Get the Details

Your best just got better.

XOS’s next generation of analyzer provides unparalleled precision with enhanced UX, improved data management, and greater ease of use.

  • LIMS integration for data management and transfer
  • Custom sample presets to save data entry time and minimize data entry error on common samples
  • Bar code reader auto fills sample name to reduce data entry time
  • Storage capacity for more than 50,000 measurement results
  • Supports up to 30 calibration curves
  • USB connectivity in front and back for connecting to printer, keyboard, mouse, and memory stick
  • Supports USB and network printers
  • Large, easy-to-remove side panels for easy serviceability
  • Advanced error reporting and diagnostics
  • Optional Autosampler to maximize productivity: 8-cup 43mm standard cup or 10-cup Accucells model

 

Product Details

Applications

  • Total chlorine analysis in petroleum products, biofuels, aromatics, and other chemicals, and water
  • For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories

Features

  • LOD: 0.13 mg/kg (ppm) at 300s, 0.09 mg/kg (ppm) at 600s for hydrocarbons, 0.3 mg/kg (ppm) at 300s, 0.2 mg/kg (ppm) at 600s for aqueous samples **
  • Dynamic Range: 0.13 mg/kg (ppm) to 4 wt%
  • Manual sulfur correction to correct for high sulfur interference
  • Easy to use:
    • Intuitive 10-inch touch screen
    • Just plug in and measure
    • Measurement time: 10-999 s
  • Low and high range available:
    • Low range: 0.13 mg/kg (ppm) – 3000 mg/kg (ppm)
    • High range: 0.3 wt% - 4 wt%
  • Extremely low maintenance: no gasses, heating elements, columns, or quartz tubing
  • Traditional XRF sample cups or XOS Accucells – decided at time of order
  • Small footprint

Specifications

Model
Clora R
Test Method
ASTM D7536 and D4929
Dimensions
42 cm (h) x 40 cm (w) x 54 cm (d)
16.5 in (h) x 15.8 in (w) x 21 in (d)
Power
100-120 VAC, 47-63 HZ at 5.0 Amps
200-240 VAC, 47-63 HZ at 2.5 Amps
Minimum Sample Cup Volume
Traditional - 5 ml, Accucells - 1 ml
Ambient Temperature Requirements
5-40° C (40-104° F)
Optical Path
Vacuum
Excitation Source
75 W air-cooled

 

Featured Content

Frequently Asked Questions; The R Series

Read the FAQ  

Precision Comparison Between UVF and MWDXRF for Biodiesel Samples

Read Whitepaper  

ASTM D2622 – Referee Sulfur Method for US Gasoline and Diesel

Read Whitepaper  

Comparison of Cl Levels in Aromatics Using MWDXRF and Microcoulometry

Read Whitepaper  

 

Contact Us

 

 lab technician using touch screen

* All qualification herein is subject to user guide specifications.

* Longer cycle time increases counts and lower LOD, but sample condition over time needs to be considered.