XOS’s next generation of analyzer provides unparalleled precision with enhanced UX, improved data management, and greater ease of use.
- LIMS integration for data management and transfer
- Custom sample presets to save data entry time and minimize data entry error on common samples
- Bar code reader auto fills sample name to reduce data entry time
- Storage capacity for more than 50,000 measurement results
- Supports up to 30 calibration curves
- USB connectivity in front and back for connecting to printer, keyboard, mouse, and memory stick
- Supports USB and network printers
- Large, easy-to-remove side panels for easy serviceability
- Advanced error reporting and diagnostics
- Optional Autosampler to maximize productivity: 8-cup 43mm standard cup or 10-cup Accucells model
- Available with Accu-flow: The Accu-flow technology allows the sample to flow continuously during measurement. This continuous flow eliminates the settling of chlorine, producing accurate and precise total chlorine results.
Product Details
Applications
- Total chlorine analysis in petroleum products, biofuels, aromatics, and other chemicals, and water
- For refineries, petrochemical and additive plants, pipeline terminals, and test laboratories
Features
- LOD: 0.13 mg/kg (ppm) at 300s, 0.09 mg/kg (ppm) at 600s for hydrocarbons, 0.3 mg/kg (ppm) at 300s, 0.2 mg/kg (ppm) at 600s for aqueous samples **
- Dynamic Range: 0.13 mg/kg (ppm) to 4 wt%
- Manual sulfur correction to correct for high sulfur interference
- Easy to use:
- Intuitive 10-inch touch screen
- Just plug in and measure
- Measurement time: 10-999 s
- Low and high range available:
- Low range: 0.13 mg/kg (ppm) – 3000 mg/kg (ppm)
- High range: 0.3 wt% - 4 wt%
- Extremely low maintenance: no gasses, heating elements, columns, or quartz tubing
- Traditional XRF sample cups or XOS Accucells – decided at time of order
- Small footprint
Specifications
Test Method
ASTM D7536 and D4929
Dimensions
42 cm (h) x 40 cm (w) x 54 cm (d)
16.5 in (h) x 15.8 in (w) x 21 in (d)
Power
100-120 VAC, 47-63 HZ at 5.0 Amps
200-240 VAC, 47-63 HZ at 2.5 Amps
Minimum Sample Cup Volume
Traditional - 5 ml, Accucells - 1 ml
Ambient Temperature Requirements
5-40° C (40-104° F)
Excitation Source
75 W air-cooled
Featured Content
Precision Comparison Between UVF and MWDXRF for Biodiesel Samples
Read Whitepaper
ASTM D2622 – Referee Sulfur Method for US Gasoline and Diesel
Read Whitepaper
Comparison of Cl Levels in Aromatics Using MWDXRF and Microcoulometry
Read Whitepaper
* All qualification herein is subject to user guide specifications.
* Longer cycle time increases counts and lower LOD, but sample condition over time needs to be considered.