XOS - US
Get eNewsletter   1.518.880.1500 Service

XRF Chlorine Analyzers

Online or on-the-bench, XOS has your chlorine analysis solution


XOS offers XRF chlorine analyzers for measuring total chlorine in liquid hydrocarbons such as aromatics, distillates, heavy fuels, crude oils, and aqueous solutions.

Discover hassle-free sample prep, easy operation, rapid testing, compliance flexibility, and industry-leading precision.


 

 

 

Clora ® R

Clora R measures total chlorine in liquid hydrocarbons when quick and reliable analysis is critical.

Methods and compliance:

  • ASTM D7536
  • ASTM D4929
Learn More

Clora ® 2XP R

Clora 2XP R analyzes total chlorine in liquid hydrocarbons with enhanced precision & performance.

Methods and compliance:

  • ASTM D7536
  • ASTM D4929
Learn More

Sindie ® +Cl

Sindie +Cl is the ideal solution to certify sulfur levels and assess chlorine for corrosion mitigation.

Methods and compliance:

  • ASTM D2622
  • ASTM D7039
  • ASTM D7536
  • ASTM D4929
  • SH / T 0842
  • ISO 20884
Learn More

Clora ® Online

Clora online delivers continuous analysis of total chlorine. Monitor crude changes (including organic chloride) of desalted crude and optimize performance.

Methods and compliance:

  • ASTM D7536
  • ATEX Zone 1
  • NEC Class 1 Div 2
Learn More

 

 

Autosamplers and Accu-Flow

Discover easy-to-use design with advanced software features for a more flexible and efficient workflow

Clora Accu-flow system

Clora ® R and Clora ® 2XP R with Autosampler

Increase your productivity with an optional autosampler to maximize productivity

Clora autosampler

Clora ® M-Series with Accu-Flow

Minimize the effects of particulate settling, common when testing for chlorides in crude oil

 

 

Contact Us

 

Advanced Analysis with MWDXRF

Monochromatic Wavelength Dispersive X-ray Fluorescence (MWDXRF) utilizes state-of-the-art focusing and monochromating optics to increase excitation intensity and dramatically improve signal-to-background ratio compared to traditional WDXRF instruments. This enables significantly improved detection limits, precision, and a reduced sensitivity to matrix effects.

A monochromatic and focused primary beam excites the sample, and secondary characteristic fluorescence X-rays are emitted from the sample. A second monochromating optic selects the chlorine-characteristic X-rays and directs these X-rays to the detector.

MWDXRF is a direct measurement technique and does not require consumable gasses or sample conversion, delivering robust and low-maintenance analyzers with dramatically lower detection limits and faster response times.

Chart depicting MWDXRF measurement technique